噪声剂量计对短持续信号响应方法研究

鲁光军 杜富荣 刘湘衡 白滢 孙勇 熊文波 舒国华

鲁光军,杜富荣,刘湘衡,等. 噪声剂量计对短持续信号响应方法研究[J]. 计量科学与技术,2021, 65(10): 45-49 doi: 10.12338/j.issn.2096-9015.2020.0415
引用本文: 鲁光军,杜富荣,刘湘衡,等. 噪声剂量计对短持续信号响应方法研究[J]. 计量科学与技术,2021, 65(10): 45-49 doi: 10.12338/j.issn.2096-9015.2020.0415
LU Guangjun, DU Furong, LIU Xiangheng, BAI Ying, SUN Yong, XIONG Wenbo, SHU Guohua. Research on Responses of Noise Dosimeters to Short-Duration Signals[J]. Metrology Science and Technology, 2021, 65(10): 45-49. doi: 10.12338/j.issn.2096-9015.2020.0415
Citation: LU Guangjun, DU Furong, LIU Xiangheng, BAI Ying, SUN Yong, XIONG Wenbo, SHU Guohua. Research on Responses of Noise Dosimeters to Short-Duration Signals[J]. Metrology Science and Technology, 2021, 65(10): 45-49. doi: 10.12338/j.issn.2096-9015.2020.0415

噪声剂量计对短持续信号响应方法研究

doi: 10.12338/j.issn.2096-9015.2020.0415
详细信息
    作者简介:

    鲁光军(1965-),甘肃省计量研究院正高级工程师,研究方向:电声测量,邮箱:lgj27@163.com

    通讯作者:

    杜富荣(1985-),甘肃省计量研究院工程师,研究方向:电声测量,邮箱:dufurong0428@126.com

    刘湘衡(1960-),湖南省声仪测控科技有限责任公司教授级高级工程师,研究方向:声学测量仪器,邮箱:liuxh4001@163.com

Research on Responses of Noise Dosimeters to Short-Duration Signals

  • 摘要: 通过研究噪声剂量计在相同幅度、频率、测量持续时间和评判标准声级下猝发音信号的噪声剂量相对于稳态信号的噪声剂量之比(即噪声剂量比),与时间平均声级(等效连续声级)、重复猝发音响应、重复时间以及单个猝发音持续时间的关系,从理论上得出了噪声剂量比对短持续信号响应的误差限。以此作为判定噪声剂量计的剂量功能是否合格的依据,并采用常用的几种噪声剂量计进行实验,实验数据均落在误差限以内。
  • 表  1  4 kHz重复猝发音的参考值及误差限

    Table  1.   Reference value and limits of the noise dose ratio for 4 kHz repetitive burst speech

    猝发音持续时间/ms猝发音重复周期/ms重复猝发音响应/dB交换率dB噪声剂量比
    参考值误差限最小值参考值最大值
    2001 000−7.0±1.030.160.1980.25
    40.250.2970.35
    50.330.3790.44
    210−7.0+1.0,−2.530.190.2970.35
    40.270.3790.44
    50.0620.1980.28
    0.251.25−7.0+1.5,−5.030.110.1980.25
    40.120.2970.39
    50.190.3790.47
    下载: 导出CSV

    表  2  1号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限

    Table  2.   Reference value and limits of the noise dose ratio of Sample 1 for the short duration signal of 4 kHz repetitive bursts

    标准评判声级交换率/dB猝发音持续时间/m s噪声剂量测得值/%噪声剂量比噪声剂量比的误差限噪声剂量相对测量不确定/%
    853连续信号6037.2参考0.31
    2001177.80.200.16~0.250.32
    21198.20.200.11~0.250.31
    0.251176.20.190.062~0.280.32
    4连续信号299.3参考0.32
    20087.70.290.25~0.350.33
    289.00.300.19~0.350.33
    0.2586.60.290.13~0.390.34
    5连续信号49.2参考0.32
    20019.70.400.33~0.440.30
    218.70.380.27~0.440.32
    0.2518.40.370.19~0.470.31
    903连续信号1888.0参考0.32
    200407.70.220.16~0.250.33
    2376.50.200.11~0.250.31
    0.25363.40.190.062~0.280.33
    904连续信号125.2参考0.32
    20037.30.300.25~0.350.34
    237.00.300.19~0.350.33
    0.2536.60.290.13~0.390.33
    5连续信号24.6参考0.32
    2009.30.380.33~0.440.32
    29.30.380.27~0.440.33
    0.259.20.370.19~0.470.35
    下载: 导出CSV

    表  3  2号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限

    Table  3.   Reference value and limits of the noise dose ratio of Sample 2 for the short duration signal of 4 kHz repetitive bursts

    标准评判声级交换率/dB猝发音持续时间/m s噪声剂量测得值/%噪声剂量比噪声剂量比的误差限噪声剂量相对测量不确定/%
    853连续信号276.10参考0.32
    20060.740.220.16~0.250.32
    255.820.200.11~0.250.33
    0.2554.630.200.062~0.280.32
    4连续信号70.55参考0.31
    20021.250.300.25~0.350.32
    220.900.300.19~0.350.33
    0.2520.380.290.13~0.390.34
    5连续信号15.34参考0.32
    2005.950.390.33~0.440.32
    25.820.380.27~0.440.32
    0.255.750.370.19~0.470.34
    903连续信号281.42参考0.31
    20060.740.220.16~0.250.32
    255.820.200.11~0.250.33
    0.2554.630.190.062~0.280.32
    4连续信号29.61参考0.30
    2009.750.330.25~0.350.31
    28.810.300.19~0.350.33
    0.258.640.290.13~0.390.33
    5连续信号7.67参考0.33
    2002.650.350.33~0.440.32
    22.890.380.27~0.440.33
    0.253.030.400.19~0.470.32
    下载: 导出CSV

    表  4  3号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限

    Table  4.   Reference value and limits of the noise dose ratio of Sample 3 for the short duration signal of 4 kHz repetitive bursts

    标准评判声级交换率/dB猝发音持续时间/m s噪声剂量测得值/%噪声剂量比噪声剂量比的误差限噪声剂量相对测量不确定/%
    903连续信号114参考0.34
    20023.50.210.16~0.250.33
    225.20.220.11~0.250.32
    0.2523.70.210.062~0.280.32
    904连续信号16.1参考0.32
    2004.620290.25~0.350.33
    24.480.280.19~0.350.32
    0.254.460.280.13~0.390.31
    5连续信号4.43参考0.336
    2001.680.380.33~0.440.33
    21.610.360.27~0.440.31
    0.251.570.350.19~0.470.32
    下载: 导出CSV

    表  5  4号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限

    Table  5.   Reference value and limits of the noise dose ratio of Sample 4 for the short duration signal of 4 kHz repetitive bursts

    标准评判声级交换率/dB猝发音持续时间/m s噪声剂量测得值/%噪声剂量比噪声剂量比的误差限噪声剂量相对测量不确定/%
    903连续信号281.42参考0.33
    20060.790.220.16~0.250.36
    255.730.200.11~0.250.32
    0.2554.600.190.062~0.280.35
    4连续信号29.61参考0.31
    2009.710.330.25~0.350.34
    28.820.300.19~0.350.32
    0.258.650.290.13~0.390.34
    5连续信号7.67参考0.33
    2002.860.370.33~0.440.35
    22.910.380.27~0.440.33
    0.252.940.380.19~0.470.34
    下载: 导出CSV
  • [1] 陈克安, 曾向阳, 李海英. 声学测量[M]. 北京: 科学出版社, 2005.
    [2] Occupational Safety and Health standards—Occupational Noise Exposure: OSHA 29CRF 1910.95[S/OL]. [2021-05-17]. https://www.docin.com/p-1762035955.html.
    [3] 蒲志强, 刘湘衡, 张国庆, 等. 声学计量术语及定义: JJF 1034-2020[S]. 北京: 中国质检出版社, 2020.
    [4] 陈剑林, 刘定洋, 张美娥. 噪声剂量计: JJG 655-1990[S]. 北京: 中国标准出版社, 1990.
    [5] 章汝威. 声学 关于空气噪声的测量及其对人影响的评价的标准指南: GB/T 14259-93[S]. 北京: 中国标准出版社, 1990.
    [6] 吴胜举, 张明铎. 声学测量原理与方法[M]. 北京: 科学出版社, 2014.
    [7] Electroacoustics—Sound level meters—Part 1: Specifications IEC 61672-1: 2013[S/OL]. [2021-05-17]. https://www.doc88.com/p-5991605238335.html.
    [8] 刘湘衡, 陈剑林, 潘月吾. 个人声暴露计: JJG 980-2003[S]. 北京: 中国计量出版社, 2003.
    [9] Specification for Personal Noise: ANSI S1.25-1991(R2007)[S/OL]. [2021-05-17]. https://www.docin.com/p-345303975.html.
    [10] 刘湘衡, 谭庆桂, 张朋万, 等. 噪声剂量计技术条件: JB/T 6824-93[S]. 北京: 机械工业部仪表综合经济研究所出版, 1993.
    [11] 许欢, 白滢, 牛峰, 等. 声级计: JJG 188-2017[S]. 北京: 中国质检出版社, 2017.
    [12] 叶德培, 赵峰, 施彦昌, 等. 测量不确定度评定与表示: JJF 1059.1-2012[S]. 北京: 中国标准出版社, 2012.
  • 加载中
计量
  • 文章访问数:  320
  • HTML全文浏览量:  91
  • PDF下载量:  36
  • 被引次数: 0
出版历程
  • 网络出版日期:  2021-07-30
  • 刊出日期:  2021-10-18

目录

    /

    返回文章
    返回