Discussion on the Influence of Uncertainty Introduced by Sample Long-term Stability on the Evaluation of Electromagnetic Compatibility Proficiency Testing Results
-
摘要: 电磁兼容能力验证计划实施周期较长,样品长期稳定性引入的不确定度不容忽视,会对能力评定标准差的计算带来较大影响,从而对结果评价造成影响。对样品长期稳定性等引入的不确定度对能力验证计划结果评价的影响进行探讨,并提出在计算能力评定标准差时应考虑样品长期稳定性等引入的不确定度,从而使得结果评价更客观合理。Abstract: Due to the long implementation period of the electromagnetic compatibility (EMC) proficiency testing program, the uncertainty introduced by the long-term stability of the samples cannot be ignored, which will have a more significant impact on the calculation of the standard deviation of the proficiency assessment and thus on the evaluation of the results. This paper discusses the influence of the uncertainties introduced by the long-term stability of samples on the evaluation of the results of the proficiency testing program, and proposes that the uncertainties introduced by the long-term stability of samples should be taken into account when calculating the standard deviation of proficiency testing, so as to evaluate the results more objective and reasonable.
-
Key words:
- EMC /
- proficiency testing /
- long-term stability /
- uncertainty /
- standard deviation
-
表 1 能力验证项目的测试结果数据
Table 1. Test result data of proficiency testing item
/dBμV 实验室
代码测试
结果实验室
代码测试
结果实验室
代码测试
结果CVC-001 43.1 CVC-007 43.3 CVC-013 43.8 CVC-002 43.6 CVC-008 41.9 CVC-014 40.3 CVC-003 42.7 CVC-009 39.0 CVC-015 43.3 CVC-004 41.7 CVC-010 43.1 CVC-016 45.1 CVC-005 42.4 CVC-011 44.2 CVC-017 44.2 CVC-006 41.9 CVC-012 42.0 CVC-018 43.8 表 2 统计量汇总
Table 2. Statistics summary
/dBμV 指定值 标准化四分位距(NIQR) σpt 43.0 1.35 1.35 表 3 统计结果
Table 3. Statistical result
实验室
代码测试结果
(dBμV)Z比
分数实验室
代码测试结果
(dBμV)Z比
分数CVC-001 43.1 0.00 CVC-010 43.8 0.00 CVC-002 43.6 0.37 CVC-011 40.3 0.81 CVC-003 42.7 −0.30 CVC-012 43.3 −0.81 CVC-004 41.7 −1.04 CVC-013 45.1 0.52 CVC-005 42.4 −0.52 CVC-014 44.2 −2.07 CVC-006 41.9 −0.89 CVC-015 43.8 0.15 CVC-007 43.3 0.15 CVC-016 43.1 1.48 CVC-008 41.9 −0.89 CVC-017 44.2 0.81 CVC-009 39.0 −3.04 CVC-018 42.0 0.52 表 4 样品长期稳定性数据
Table 4. Long-term stability data of samples
/dBμV 测试时间 测试值 测试时间 测试值 测试时间 测试值 第1月上 42.99 第2月下 42.88 第6月中 42.65 第1月中 42.74 第3月中 42.83 第8月中 43.22 第1月下 42.18 第4月中 43.01 第10月中 43.05 第2月上 42.95 第5月中 42.85 第12月下 42.93 表 5 样品长期稳定性引入的不确定度分析结果
Table 5. Results of uncertainty analysis for long-term stability of samples
/dBμV 统计量 F统计值 P值 sb Sb=12×sb 统计结果 1.78 0.21 0.021 0.252 表 6 统计结果表
Table 6. Table of statistical results
/dBμV 实验室代码 测试结果 Z比分数(不考虑样品长期稳定性的不确定度,σpt=1.35) Z比分数(考虑12个月样品稳定性的不确定度,σpt=1.38) CVC-001 43.1 0.00 0.00 CVC-002 43.6 0.37 0.36 CVC-003 42.7 −0.30 −0.29 CVC-004 41.7 −1.04 −1.01 CVC-005 42.4 −0.52 −0.51 CVC-006 41.9 −0.89 −0.87 CVC-007 43.3 0.15 0.14 CVC-008 41.9 −0.89 −0.87 CVC-009 39.0 −3.04 −2.97 CVC-010 43.8 0.00 0.00 CVC-011 40.3 0.81 0.80 CVC-012 43.3 −0.81 −0.80 CVC-013 45.1 0.52 0.51 CVC-014 44.2 −2.07 −2.03 CVC-015 43.8 0.15 0.14 CVC-016 43.1 1.48 1.45 CVC-017 44.2 0.81 0.80 CVC-018 42.0 0.52 0.51 表 7 统计结果表
Table 7. Table of statistical results
/dBμV 实验室
代码测试
结果Z比分数(不考虑样品稳定性不确定度,σpt=1.35) Z比分数(考虑样品12个月的稳定性不确定度,σpt=1.38) Z比分数(考虑样品18个月的稳定性不确定度,σpt=1.405) CVC-001 43.1 0.00 0.00 0.00 CVC-002 43.6 0.37 0.36 0.36 CVC-003 42.7 −0.30 −0.29 −0.28 CVC-004 41.7 −1.04 −1.01 −1.00 CVC-005 42.4 −0.52 −0.51 −0.50 CVC-006 41.9 −0.89 −0.87 −0.85 CVC-007 43.3 0.15 0.14 0.14 CVC-008 41.9 −0.89 −0.87 −0.85 CVC-009 39.0 −3.04 −2.97 −2.92 CVC-010 43.8 0.00 0.00 0.00 CVC-011 40.3 0.81 0.80 0.78 CVC-012 43.3 −0.81 −0.80 −0.78 CVC-013 45.1 0.52 0.51 0.50 CVC-014 44.2 −2.07 −2.03 −1.99 CVC-015 43.8 0.15 0.14 0.14 CVC-016 43.1 1.48 1.45 1.42 CVC-017 44.2 0.81 0.80 0.78 CVC-018 42.0 0.52 0.51 0.50 表 8 统计结果
Table 8. Table of statistical results
/dBμV 实验室
代码测试
结果Z比分数(不考虑样品稳定性不确定度时,σpt=1.35) Z比分数(考虑样品12个月的稳定性不确定度时,σpt=1.38) Z比分数(考虑样品12个月的稳定性不确定度及样品不均匀度时,σpt=1.39) CVC-001 43.1 0.00 0.00 0.00 CVC-002 43.6 0.37 0.36 0.36 CVC-003 42.7 −0.30 −0.29 −0.29 CVC-004 41.7 −1.04 −1.01 −1.01 CVC-005 42.4 −0.52 −0.51 −0.50 CVC-006 41.9 −0.89 −0.87 −0.86 CVC-007 43.3 0.15 0.14 0.14 CVC-008 41.9 −0.89 −0.87 −0.86 CVC-009 39.0 −3.04 −2.97 −2.95 CVC-010 43.8 0.00 0.00 0.00 CVC-011 40.3 0.81 0.80 0.79 CVC-012 43.3 −0.81 −0.80 −0.79 CVC-013 45.1 0.52 0.51 0.50 CVC-014 44.2 −2.07 −2.03 −2.01 CVC-015 43.8 0.15 0.14 0.14 CVC-016 43.1 1.48 1.45 1.44 CVC-017 44.2 0.81 0.80 0.79 CVC-018 42.0 0.52 0.51 0.50 -
[1] ISO. Statistical methods for use in proficiency testing by interlaboratory comparisons: ISO 13528: 2015 [S]. ISO, 2015. [2] ISO. Conformity assessment General requirements for proficiency testing: ISO/IEC 17043: 2010 [S]. ISO, 2010. [3] 中国合格评定国家认可委员会. 合格评定能力验证的通用要求: GB/T 27043-2012 [S]. 北京: 中国标准出版社, 2012. [4] 中国合格评定国家认可委员会. 能力验证的选择核查与利用指南: CNAS-GL032-2018 [S]. 北京: 中国标准出版社, 2018. [5] 中国合格评定国家认可委员会. 能力验证结果的统计处理和能力评价指南: CNAS-GL002 [S]. 北京: 中国标准出版社, 2018. [6] 中国合格评定国家认可委员会. 能力验证样品均匀性和稳定性评价指南: CNAS-GL003 [S]. 北京: 中国标准出版社, 2018. [7] IEC. Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission: CISPR 14-1: 2020 [S]. IEC, 2020. [8] CISPR. Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests: CISPR/TR 16-4-1: 2009 [S]. CISPR, 2009. [9] CISPR. Specification for radio disturbance and immunity measuring apparatus and methods–Part 4-2: Uncertainties, statistics and limit modelling–Measurement instrumentation uncertainty: CISPR 16-4-2: 2018 [S]. CISPR, 2018. [10] 陈魁. 试验设计与分析 [M]. 第2版. 北京: 清华大学出版社, 2005. [11] 范金城, 吴可法. 统计推断导引[M]. 北京: 科学出版社, 2001. [12] 何晓群. 六西格玛数据分析技术[M]北京: 中国人民大学出版社, 2004. [13] 陈钧. 能力验证结果统计处理中几种改进的稳健算法[J]. 计量技术, 2010(12): 3. [14] 陈钧, 朱珈. 一元线性回归分析在能力验证样品稳定性检验中的应用[J]. 计量技术, 2013(1): 72-73,80. [15] 陈钧, 罗燕平. 基于全检情形下的能力验证样品均匀性评价方法探讨[J]. 计量技术, 2017(1): 68-71. [16] 陈钧, 李秀青. 关于“六西格玛”与能力验证相结合的探讨[J]. 日用电器, 2020(7): 15-17.