Feasibility Study for Calibration of Precision Thermometers With Thermostatic Calorimeters
-
摘要: 随着测温精度高达1 mK甚至0.1 mK的精密温度计在实验设备和航空航天装备上的大量应用,对精密温度计量值溯源中使用的恒温槽的控温精度提出了更高要求,需要研究一种控温精度小于万分之一的恒温槽来满足其量值溯源需求。利用恒温式量热仪控温模式搭建检测精密温度计恒温槽的模型,通过理论分析和实验验证,该恒温槽模型可满足测温精度为1 mK甚至0.1 mK的精密温度计的校准要求。Abstract: With the large-scale application of precision thermometers with a temperature measurement accuracy of up to 1 mK or even 0.1 mK in experimental equipment and aerospace equipment, higher requirements are placed on the temperature control accuracy of the thermostatic bath used in the traceability of precision temperature measurement values. A thermostatic bath with a temperature control accuracy of less than 1/10,000 to meet the traceability requirements of its value. In this paper, the model of the thermostatic bath for testing precision thermometers is built by using the thermostatic calorimeter temperature control mode, and through theoretical analysis and experimental verification, the thermostatic bath model can meet the calibration requirements of precision thermometers with a temperature measurement accuracy of 1 mK or even 0.1 mK.
-
表 1 恒温槽常用介质使用温度范围
Table 1. Operating temperature range of common medium in thermostatic bath
介质名称 温度范围 水 (室温+5℃)~95℃ 酒精(75%, V/V) −30℃~20℃ 酒精(>95%, V/V) −80℃~20℃ 防冻液 −40℃~110℃ 食用油 90℃~200℃ 变压器油 (室温+5℃)~150℃ 基础油、汽缸油 150℃~300℃ 甲基硅油10 cs −40℃~20℃ 甲基硅油100 cs 30℃~200℃ 表 2 待测数字温度计采集的温度统计表
Table 2. The temperature statistics collected by the digital thermometer to be tested
时间(s) 采集温度(℃) 时间(s) 采集温度(℃) 1 31.36959 21 31.37135 2 31.36979 22 31.37145 3 31.36995 23 31.37154 4 31.36997 24 31.37167 5 31.37001 25 31.37177 6 31.37014 26 31.37177 7 31.37017 27 31.37193 8 31.37038 28 31.372 9 31.37037 29 31.37208 10 31.37048 30 31.3722 11 31.37057 31 31.37222 12 31.37068 32 31.37237 13 31.37079 33 31.3724 14 31.37086 34 31.37252 15 31.37093 35 31.37253 16 31.37101 36 31.37261 17 31.37111 37 31.37275 18 31.37117 38 31.37282 19 31.37128 39 31.3729 20 31.37135 40 31.373 表 3 待测数字温度计精度分析
Table 3. Accuracy analysis of digital thermometer to be tested
序号 实测(℃) 真值(℃) 误差(℃) 序号 实测(℃) 真值(℃) 误差(℃) 1 31.36959 31.36980003 0.00021003 21 31.37135 31.37140803 0.00005803 2 31.36979 31.36988043 0.00009043 22 31.37145 31.37148843 0.00003843 3 31.36995 31.36996083 0.00001083 23 31.37154 31.37156883 0.00002883 4 31.36997 31.37004123 0.00007123 24 31.37167 31.37164923 −0.00002077 5 31.37001 31.37012163 0.00011163 25 31.37177 31.37172963 −0.00004037 6 31.37014 31.37020203 0.00006203 26 31.37177 31.37181003 0.00004003 7 31.37017 31.37028243 0.00011243 27 31.37193 31.37189043 −0.00003957 8 31.37038 31.37036283 −0.00001717 28 31.37200 31.37197083 −0.00002917 9 31.37037 31.37044323 0.00007323 29 31.37208 31.37205123 −0.00002877 10 31.37048 31.37052363 0.00004363 30 31.37220 31.37213163 −0.00006837 11 31.37057 31.37060403 0.00003403 31 31.37222 31.37221203 −0.00000797 12 31.37068 31.37068443 0.00000443 32 31.37237 31.37229243 −0.00007757 13 31.37079 31.37076483 −0.00002517 33 31.37240 31.37237283 −0.00002717 14 31.37086 31.37084523 −0.00001477 34 31.37252 31.37245323 −0.00006677 15 31.37093 31.37092563 −0.00000437 35 31.37253 31.37253363 0.00000363 16 31.37101 31.37100603 −0.00000397 36 31.37261 31.37261403 0.00000403 17 31.37111 31.37108643 −0.00002357 37 31.37275 31.37269443 −0.00005557 18 31.37117 31.37116683 −0.00000317 38 31.37282 31.37277483 −0.00004517 19 31.37128 31.37124723 −0.00003277 39 31.37290 31.37285523 −0.00004477 20 31.37135 31.37132763 −0.00002237 40 31.37300 31.37293563 −0.00006437 s 0.00005920 μ 31.3713 查表t0.01(39) 2.708 -
[1] 周琨荔, 韩琪娜, 屈继峰, 等. 噪声法测量玻尔兹曼常数研究综述[J]. 计量技术, 2019(5): 47-51. [2] 王海涛, 董亮, 孙云飞, 等. 基于LabVIEW的油面温控器自动校准系统的研究[J]. 计量技术, 2018(9): 46-48. [3] 崔馨元, 刘亚兵. 一种标准铂电阻温度计自动检定系统的研制[J]. 计量科学与技术, 2020(11): 29-32. doi: 10.3969/j.issn.2096-9015.2020.11.06 [4] 陈旭, 孙力, 凌彦萃. 温度校准仪热电偶档基于冷端补偿的校准方法研究[J]. 中国测试, 2018, 44(12): 96-100. doi: 10.11857/j.issn.1674-5124.2018.12.017 [5] 胡芃, 陈则韶, 罗大为, 等. 制冷工质PVT实验用精密低温恒温槽的研制[J]. 仪器仪表学报, 2002(4): 414-416,426. doi: 10.3321/j.issn:0254-3087.2002.04.023 [6] 杨明霞. 高精度铂电阻测温系统设计[D]. 天津: 天津工业大学, 2019. [7] 刘颖, 刘义平, 任婷婷, 等. 不同曲线拟合方式对NTC热敏电阻测温精度的影响[J]. 中国测试, 2018, 44(S1): 200-204. [8] 徐刚. 基于STM32的高精度恒温槽的研制[D]. 南京: 南京信息工程大学, 2020. [9] 杨焕诚. 智能置换式恒温槽测量系统的应用研究[J]. 计量学报, 2019, 40(6): 1037-1042. doi: 10.3969/j.issn.1000-1158.2019.06.16 [10] 许方鹏. 高精度恒温槽的设计与温场特性研究[D]. 泰安: 山东农业大学, 2019. [11] 梁嘉琪, 董浩斌, 葛健. 多传感器高准确度便携式温度测量仪[J]. 中国测试, 2016, 42(5): 70-74. doi: 10.11857/j.issn.1674-5124.2016.05.015 [12] 李希靖, 李文军, 陈颖, 等. 由测温随机过程的一个实现估算数据方差的新方法[J]. 机械工程学报, 1995(4): 31-35. [13] 王海涛, 文萌, 董亮, 等. 恒温槽温度梯度实验研究[J]. 计量科学与技术, 2021, 65(10): 50-53,5. doi: 10.12338/j.issn.2096-9015.2019.0070 [14] 李争, 史雁鹏, 杜深慧, 等. 永磁电机自然散热及水冷系统分析[J]. 三峡大学学报(自然科学版), 2019, 41(6): 86-91. doi: 10.13393/j.cnki.issn.1672-948x.2019.06.017 [15] 龙新峰, 于兴鲁, 毛青松. 太阳能腔式吸热器自然对流热损的数值研究[J]. 河北科技大学学报, 2012, 33(1): 44-49. doi: 10.7535/hbkd.2012yx01011