基于微小质量自动测量系统的数据处理方法研究

彭程 王健 王肖磊 吴頔 钟瑞麟 胡满红

彭程,王健,王肖磊,等. 基于微小质量自动测量系统的数据处理方法研究[J]. 计量科学与技术,2022, 66(5): 29-36 doi: 10.12338/j.issn.2096-9015.2021.0648
引用本文: 彭程,王健,王肖磊,等. 基于微小质量自动测量系统的数据处理方法研究[J]. 计量科学与技术,2022, 66(5): 29-36 doi: 10.12338/j.issn.2096-9015.2021.0648
PENG Cheng, WANG Jian, WANG Xiaolei, WU Di, ZHONG Ruilin, HU Manhong. Research on Data Processing Method Based on Automatic Measurement System of Mass in Small Nominal Value[J]. Metrology Science and Technology, 2022, 66(5): 29-36. doi: 10.12338/j.issn.2096-9015.2021.0648
Citation: PENG Cheng, WANG Jian, WANG Xiaolei, WU Di, ZHONG Ruilin, HU Manhong. Research on Data Processing Method Based on Automatic Measurement System of Mass in Small Nominal Value[J]. Metrology Science and Technology, 2022, 66(5): 29-36. doi: 10.12338/j.issn.2096-9015.2021.0648

基于微小质量自动测量系统的数据处理方法研究

doi: 10.12338/j.issn.2096-9015.2021.0648
基金项目: 国家自然科学基金面上项目(52075515)。
详细信息
    作者简介:

    彭程(1995-),中国计量科学研究院研究实习员,研究方向:质量量值传递、高精度单晶硅球质量测量方法等,邮箱:pengcheng@nim.ac.cn

    通讯作者:

    王健(1977-),中国计量科学研究院研究员,研究方向:质量计量技术、衡器计量技术、机电控制系统设计,邮箱:wjian@nim.ac.cn

Research on Data Processing Method Based on Automatic Measurement System of Mass in Small Nominal Value

  • 摘要: 为提升检测效率,实验室逐步采用质量自动测量系统代替人工测量。目前质量自动测量系统直接生成的数据侧重对测量结果的呈现,但缺少ISO 17025中对原始记录及证书报告编制工作要求的关键信息要素,同时开展微小质量测量时容易因砝码掉落造成测量中断生成非完整数据,测量结束后往往需要检测人员对数据进行拼接重组、人为汇总计算、手动录入环境条件及委托单信息等,因此在实际检测工作中,自动测量系统的数据分析及处理过程仍需耗费大量人力。结合微小质量测量工作特点,基于质量自动测量系统提出了测量数据自动处理的改进方法,增加检测数据自动切分重组、超差判定、非完整数据处理等功能,实现数据自动分析、原始记录及证书报告的自动生成,减少人为因素干扰,进一步提升质量检测效率与数据自动化处理分析能力。
  • 图  1  微小质量砝码测量过程中存在的掉落情况

    Figure  1.  Dropping situation during the measurement of weight in small nominal value

    图  2  数据自动化处理程序流程图

    Figure  2.  Flow chart of automated data processing procedures

    图  3  质量自动测量系统测量序列号编码规则示意图

    Figure  3.  Schematic diagram of coding rules for sequence numbers of automatic mass measurement system

    图  4  数据切分、重组处理操作界面

    Figure  4.  Data segmentation and reorganization processing

    图  5  数据计算操作界面

    Figure  5.  Data calculation operation interface

    图  6  补充数据操作界面

    Figure  6.  Supplementary data operation interface

    图  7  超差数据自动标记

    Figure  7.  Automatic flagging of out-of-range data

    图  8  砝码检定证书报告自动生成范例

    Figure  8.  Example of automatic generation of certificate report

    表  1  由质量自动测量系统直接生成的测量记录保存信息

    Table  1.   Measurement record directly generated by the automatic mass measurement system

    日期测量时间测量序列测量工位示值差值差值均值修正值标准差
    2021/10/813:22:55010101Ac4499.9928
    2021/10/813:24:03010101Ba1499.9975
    2021/10/813:25:11010101Ac4499.99210.00507
    2021/10/813:26:19010102Ba1499.9970
    2021/10/813:27:26010102Ac4499.9921
    2021/10/813:28:34010102Ba1499.99670.004730.004900.002600.00024
    2021/10/813:29:43010201Ac5200.0011
    2021/10/813:30:51010201Ba2200.0120
    2021/10/813:31:59010201Ac5200.00090.01100
    2021/10/813:33:07010202Ba2200.0119
    2021/10/813:34:16010202Ac5200.0010
    2021/10/813:35:24010202Ba2200.01190.010900.010950.013950.00007
    下载: 导出CSV
  • [1] 杨囡, 王健, 任孝平. 自动无扰动系统的微克质量标准研究[J]. 中国计量学院学报, 2015, 26(2): 172-187.
    [2] Kim M S, Pratt J R. SI traceability: Current status and future trends for forces below 10 microNewtons[J]. Measurement, 2010, 43(2): 169-182. doi: 10.1016/j.measurement.2009.09.005
    [3] Madec T, Mann G, Meury P A, et al. Micro-mass standards to calibrate the sensitivity of mass comparators[J]. Metrologia, 2007, 44(5): 266-274. doi: 10.1088/0026-1394/44/5/002
    [4] Ren X, Cai C, Yi L, et al. Mass Metrology Based on Robotic Mass Measurement System[J]. Lecture Notes in Electrical Engineering, 2013, 254: 477-484.
    [5] T Fehling, T Frohlich, D Heydenbluth. Design and Performance of the new Sartorius Robot-System[C]. IMEKO. 20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007, 2009: 95-102.
    [6] Gordon P, Stuart D. Design and Assessment of an Automatic 50 kg Weight Exchanger[C]. Measurement Science Conference 1970-2005 Proceedings, 2005: 268-277.
    [7] 王肖磊, 王健, 钟瑞麟, 等. 精密空气密度测量装置的研制[J]. 计量技术, 2010(10): 18-20.
    [8] Arthur R. A New Mass Comparator Generation for the Automatic Calibration of Weight Sets[C]. International Measurement Confederation. Proceedings of the 17th international conference on force, mass, torque and pressure measurements. Istanbul, Turkey, 2001: 310-319.
    [9] BIPM. International Recommendation Weights of Classes E1, E2, F1, F2, M1, M1-2, M2, M2-3 and M3, Part 1: Metrological and technical requirements: OIML R 111-1 [S]. Switzerland, 2004.
    [10] Lee W G, Choi N Y. Calibration Designs Of Mass Standards For 2 Comparators In A Decade Series[C]. XVI Imeko World Congress Imeko 2000, Proceedings Volume III, 2000: 157-160.
    [11] 国家质量监督检验检疫总局. 砝码检定规程: JJG 99-2006 [S]. 北京: 中国计量出版社, 2006.
    [12] Schwartz R. Guide to mass determination with high accuracy[J]. Physikalisch-Technisch Bundesanstalt, Braunschweig, 1995, 4: 40.
    [13] Ulrich J G. A Special Weight Set for the Determination of OIML Weight Sets and Its Use[J]. Bulletin OIML, 1989, 12: 14.
    [14] Fröhlich T, Fehling T, Heydenbluth D. Mass Dissemination using a Robot System[J]. Technisches Messen:Sensoren, Gerate, Systeme, 2009, 76(7-8): 382-387.
    [15] Zoltan Z. New Primary Balance Of Bev For High-Precision Mass Determination And Realization of The Mass Scale In The Range From 10 g up to 1 kg[C]. International Measurement Federation. 20th IMEKO world congress 2012: 20th IMEKO (International Measurement Federation) world congress, 2012: 9-14.
    [16] Frohlich T, Fehling T, Gatzemeier B, et al. Mass dissemination using a fully automated mass comparator robot system[C]. IMEKO. 20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque, 2007.
    [17] 彭程, 王健. 用于量值传递的高精度单晶硅球质量测量研究[J]. 计量学报, 2021, 42(3): 265-270. doi: 10.3969/j.issn.1000-1158.2021.03.01
    [18] 罗志勇, 刘子勇, 刘吉萍, 等. 便携式空气密度精密测量仪的研制[J]. 计量学报, 2001, 22(1): 52-56. doi: 10.3321/j.issn:1000-1158.2001.01.010
    [19] 王肖磊, 王健, 钟瑞麟, 等. 砝码质量测量中的空气密度测量装置的研究[J]. 计量学报, 2011, 32(1): 41-43.
    [20] 王健, 钟瑞麟, 蔡常青, 等. 一种新型衡器自动测量系统[J]. 计量学报, 2012, 33(5): 421-422.