扭矩倍增器校准方法及测量不确定度评估

    Torque Multiplier Calibration Method and Measurement Uncertainty Assessment

    • 摘要: 通过对国内已知的三种扭矩倍增器校准方法的比较,分析其校准方法及计算结果的差别,指出当前存在校准方法不统一,校准数据处理不一致,结果评价和分析不全面的问题。通过对现有扭矩倍增器测量结果不确定度评定过程的分析,指出其存在测量模型不完善以及不确定度来源分析不全面的问题,并给出以倍增器实际使用参数(放大倍率)为评价对象的测量不确定度评定方法及过程。评定结果分析可知,当测量输入扭矩和输出扭矩的扭矩测试仪由同一上级标准溯源时,可以减小扭矩倍增器的测量不确定度。

       

      Abstract: By comparing the three known torque multiplier calibration methods in China, the differences in their calibration methods and calculation results are analyzed, and the problems of inconsistent calibration methods, inconsistent calibration data processing, and incomplete evaluation and analysis of results are pointed out. By analyzing the uncertainty evaluation process of the existing torque multipliers, it is pointed out that there are problems of imperfect measurement models and incomplete analysis of uncertainty sources, and the measurement uncertainty evaluation method and process are given with the actual use parameter (magnification) of the multipliers as the evaluation object. The analysis of the evaluation results shows that the measurement uncertainty of the torque multiplier can be reduced when the torque tester measuring the input torque and the output torque is traced by the same superior standard.

       

    /