摘要: 提高火车灌装计量系统的准确性,能够更有效地发挥火车罐装系统计量的作用,避免火车罐装系统日常出现的超装、欠装现象,有效解决火车罐装工作滞后、检尺计量和销售货运工作延缓等问题。通过对装车质量流量计和装车工艺进行现场排查,查找分析出误差产生的主要原因,并提出切实有效的解决措施,火车罐装效率明显提升,大大缩减了检尺人工劳动量。Abstract: To improve the accuracy of the train filling and measuring system is important for maximizing the utility of system, including avoiding over-loading and under-loading, and reducing delay of the filling work, measuring by ruler, and sales and freight transportation. Through an on-site investigation of a loading mass flowmeter and the loading process, the main factors causing errors were analyzed, and practical and effective solutions were put forward. The efficiency of the train tank loading was obviously improved and the manual labor for gauging was greatly reduced.
-
Key words:
- metering system /
- accuracy /
- data comparison /
- measurement accuracy /
- trade settlement
-
表 1 检尺与装车质量流量计计量系统比对汇总表一
Table 1. Comparison between ruler checking and a loading mass flowmeter
序号 罐装总数/节 比对合格数/节 比对合格率/% 1 50 9 18.0 2 50 21 42.0 3 48 24 50.0 4 51 25 49.0 5 51 10 19.6 6 50 29 58.0 7 50 28 56.0 总计 350 146 41.7 表 2 检尺与装车质量流量计计量系统比对汇总表二
Table 2. Comparison between ruler checking and the loading mass flowmeter after correction (#1)
序号 罐装总数/节 比对合格数/节 比对合格率/% 1 57 44 77.2 2 51 35 68.6 3 55 41 74.5 4 50 36 72.0 5 56 47 83.9 6 50 36 72.0 7 55 42 76.4 总计 350 281 75.1 表 3 检尺与装车质量流量计计量系统比对汇总表三
Table 3. Comparison between ruler checking and the loading mass flowmeter after correction (#2)
序号 罐装总数/节 比对合格数/节 比对合格率/% 1 55 49 89.1 2 44 36 81.8 3 55 50 90.9 总计 154 135 87.8 -
[1] 李景玉. 定量装车计算机控制系统的实现[J]. 石油化工自动化, 2001(2): 73-74. doi: 10.3969/j.issn.1007-7324.2001.02.024 [2] 王丹丹. 成品油出厂与批量控制[J]. 石油化工自动化, 2001(4): 32-33. doi: 10.3969/j.issn.1007-7324.2001.04.010 [3] 李英华, 何力. 罐内液体石油产品计量技术规范: JJF1014-1989. 北京: 中国标准出版社, 1989. [4] 武胜林. 质量流量计超差原因分析[J]. 石油化工自动化, 1999(4): 66-69. [5] 肖素琴. 油品计量员读本[M]. 第3版. 北京: 中国石化出版社, 2016: 231-239. [6] 连琴, 丁遵义. 油品铁路罐车计量中的误差分析[J]. 中国高新技术企业, 2008(13): 100-101. doi: 10.3969/j.issn.1009-2374.2008.13.081 [7] 陈陆平. 如何减少油品计量中的误差[J]. 中国计量, 1999(8): 45-46. doi: 10.3969/j.issn.1006-9364.1999.08.040 [8] 纪纲. 流量测量仪表应用技巧[M]. 第2版. 北京: 化学工业出版社, 2014: 141-151. [9] 金德玺. 石油和液体石油产品温度测量法(手工法): GB/T8927—2008[S]. 北京: 中国标准出版社, 2008. [10] 管焕铮, 薄艳红. 原油和液体石油产品密度实验室测定法(密度计法): GB/T1884-2000[S]. 北京: 中国标准出版社, 2000. [11] 金德玺. 石油和液体石油产品液位测量法(手工法): GB/T 13894—1992[S]. 北京: 中国标准出版社, 1992. [12] 魏进祥, 刘峰阳. 石油液体手工取样法: GB/T 4756-2015[S]. 北京: 中国标准出版社, 2015.