Discussions on PCR Calibration Devices
-
Abstract: With the development of biotechnology, the demand for PCR calibration has risen sharply. This paper decribes the PCR process and proposes a PCR calibration device, which can realize the temperature calibration for PCR devices.
-
Key words:
- PCR /
- amplification technology /
- calibration device
-
表 1 热电偶检测结果
Table 1. Measurement results with a thermocouple as the standard
设定温
度(℃)最高温
度(℃)最低温
度(℃)平均温
度 (℃)温度均
匀性(℃)平均升温
速率(℃/s)平均降温
速性率(℃/s)30.0 30.9 29.5 30.4 1.4 1.4 1.3 50.0 51.0 49.8 50.7 1.2 60.0 60.6 59.2 60.5 1.4 70.0 70.8 69.5 70.4 1.3 90.0 90.5 89.4 90.3 1.1 95.0 95.2 94.1 94.8 1.1 表 2 PCR仪校准装置检测结果
Table 2. Measurement results with the PCR calibration device as the standard
设定温
度(℃)最高温
度(℃)最低温
度(℃)平均温
度(℃)温度均
匀性(℃)平均升温
速率(℃/s)平均降温速
率率(℃/s)30.0 30.44 30.10 30.16 0.34 2.85 1.44 50.0 50.60 50.30 50.32 0.30 60.0 60.38 60.01 60.15 0.37 70.0 70.44 70.13 70.28 0.31 90.0 90.24 89.89 90.15 0.35 95.0 95.42 95.06 95.17 0.36 -
[1] 阮瑞雯. 基于温度巡检仪的PCR仪温度校准装置研究[D]. 广州: 华南理工大学, 2018. [2] 杨婉荣. PCR仪温度控制系统的研究与设计[D]. 西安: 西安工业大学, 2014. [3] 朱晨彬, 朱毅晨, 姚丽芳,等. 浅谈PCR仪温度校准的必要性及方法[J]. 工业计量, 2013, 23(1): 1-2,11. doi: 10.3969/j.issn.1002-1183.2013.01.001 [4] 高运华. JJF1527-2015《聚合酶链反应分析仪校准规范》解读[J]. 中国计量, 2016(8): 117-118. [5] 张丽萍, 朱毅晨, 张振彦. 基因扩增仪测温系统校准方法的研究[J]. 中国计量, 2016(2): 103-104. [6] 罗曼. 浅谈基因扩增仪检测技术[J]. 计量与测试技术, 2015, 42(3): 67-68. [7] 戴红, 卢进才. PCR仪温度校准现状分析[J]. 广东化工, 2017, 44(17): 104, 113. [8] 卢旋. 对于PCR设备温度验证的一些看法[J]. 工业计量, 2017, 27(S1): 133-134. [9] 曾颖. PCR仪温度校准的研究[J]. 科技视界, 2016(13): 20-21. doi: 10.3969/j.issn.2095-2457.2016.13.010 [10] 张丽萍. 基因扩增仪(PCR仪)温度校准装置的研究[D]. 天津: 天津大学, 2012. [11] 林军. 多通道高准确度温度监测系统的研究[J]. 计量与测试技术, 2013, 40(3): 1-3. doi: 10.3969/j.issn.1004-6941.2013.03.001 [12] 王金. 便携式PCR仪温控系统设计与仿真研究[M]. 大连: 大连海事大学, 2015.