Research on Responses of Noise Dosimeters to Short-Duration Signals
-
摘要: 通过研究噪声剂量计在相同幅度、频率、测量持续时间和评判标准声级下猝发音信号的噪声剂量相对于稳态信号的噪声剂量之比(即噪声剂量比),与时间平均声级(等效连续声级)、重复猝发音响应、重复时间以及单个猝发音持续时间的关系,从理论上得出了噪声剂量比对短持续信号响应的误差限。以此作为判定噪声剂量计的剂量功能是否合格的依据,并采用常用的几种噪声剂量计进行实验,实验数据均落在误差限以内。Abstract: This paper proposes acceptance limits for the nosie dose ratio of noise dosimeters. The ratio of the noise dose of a sound burst signal to the noise dose of the steady-state signal under the same amplitude, frequency, measurement duration and judgment standard sound level, i.e. the noise dose ratio, of a noise dosimeter is studied. The dependence of the noise dose ratio on the time average sound level (i.e. equivalent continuous sound level), repetitive tone burst response, repetition time, and the duration of a single tone burst is also studied. The acceptance limits were used as criteria to evaluate the performance of several noise dosimeters and the test results lay within the limits.
-
Key words:
- noise dosimeter /
- noise dose /
- time-average sound level /
- exchange rate
-
表 1 4 kHz重复猝发音的参考值及误差限
Table 1. Reference value and limits of the noise dose ratio for 4 kHz repetitive burst speech
猝发音持续时间/ms 猝发音重复周期/ms 重复猝发音响应/dB 交换率dB 噪声剂量比 参考值 误差限 最小值 参考值 最大值 200 1 000 −7.0 ±1.0 3 0.16 0.198 0.25 4 0.25 0.297 0.35 5 0.33 0.379 0.44 2 10 −7.0 +1.0,−2.5 3 0.19 0.297 0.35 4 0.27 0.379 0.44 5 0.062 0.198 0.28 0.25 1.25 −7.0 +1.5,−5.0 3 0.11 0.198 0.25 4 0.12 0.297 0.39 5 0.19 0.379 0.47 表 2 1号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限
Table 2. Reference value and limits of the noise dose ratio of Sample 1 for the short duration signal of 4 kHz repetitive bursts
标准评判声级 交换率/dB 猝发音持续时间/m s 噪声剂量测得值/% 噪声剂量比 噪声剂量比的误差限 噪声剂量相对测量不确定/% 85 3 连续信号 6037.2 参考 0.31 200 1177.8 0.20 0.16~0.25 0.32 2 1198.2 0.20 0.11~0.25 0.31 0.25 1176.2 0.19 0.062~0.28 0.32 4 连续信号 299.3 参考 0.32 200 87.7 0.29 0.25~0.35 0.33 2 89.0 0.30 0.19~0.35 0.33 0.25 86.6 0.29 0.13~0.39 0.34 5 连续信号 49.2 参考 0.32 200 19.7 0.40 0.33~0.44 0.30 2 18.7 0.38 0.27~0.44 0.32 0.25 18.4 0.37 0.19~0.47 0.31 90 3 连续信号 1888.0 参考 0.32 200 407.7 0.22 0.16~0.25 0.33 2 376.5 0.20 0.11~0.25 0.31 0.25 363.4 0.19 0.062~0.28 0.33 90 4 连续信号 125.2 参考 0.32 200 37.3 0.30 0.25~0.35 0.34 2 37.0 0.30 0.19~0.35 0.33 0.25 36.6 0.29 0.13~0.39 0.33 5 连续信号 24.6 参考 0.32 200 9.3 0.38 0.33~0.44 0.32 2 9.3 0.38 0.27~0.44 0.33 0.25 9.2 0.37 0.19~0.47 0.35 表 3 2号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限
Table 3. Reference value and limits of the noise dose ratio of Sample 2 for the short duration signal of 4 kHz repetitive bursts
标准评判声级 交换率/dB 猝发音持续时间/m s 噪声剂量测得值/% 噪声剂量比 噪声剂量比的误差限 噪声剂量相对测量不确定/% 85 3 连续信号 276.10 参考 0.32 200 60.74 0.22 0.16~0.25 0.32 2 55.82 0.20 0.11~0.25 0.33 0.25 54.63 0.20 0.062~0.28 0.32 4 连续信号 70.55 参考 0.31 200 21.25 0.30 0.25~0.35 0.32 2 20.90 0.30 0.19~0.35 0.33 0.25 20.38 0.29 0.13~0.39 0.34 5 连续信号 15.34 参考 0.32 200 5.95 0.39 0.33~0.44 0.32 2 5.82 0.38 0.27~0.44 0.32 0.25 5.75 0.37 0.19~0.47 0.34 90 3 连续信号 281.42 参考 0.31 200 60.74 0.22 0.16~0.25 0.32 2 55.82 0.20 0.11~0.25 0.33 0.25 54.63 0.19 0.062~0.28 0.32 4 连续信号 29.61 参考 0.30 200 9.75 0.33 0.25~0.35 0.31 2 8.81 0.30 0.19~0.35 0.33 0.25 8.64 0.29 0.13~0.39 0.33 5 连续信号 7.67 参考 0.33 200 2.65 0.35 0.33~0.44 0.32 2 2.89 0.38 0.27~0.44 0.33 0.25 3.03 0.40 0.19~0.47 0.32 表 4 3号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限
Table 4. Reference value and limits of the noise dose ratio of Sample 3 for the short duration signal of 4 kHz repetitive bursts
标准评判声级 交换率/dB 猝发音持续时间/m s 噪声剂量测得值/% 噪声剂量比 噪声剂量比的误差限 噪声剂量相对测量不确定/% 90 3 连续信号 114 参考 0.34 200 23.5 0.21 0.16~0.25 0.33 2 25.2 0.22 0.11~0.25 0.32 0.25 23.7 0.21 0.062~0.28 0.32 90 4 连续信号 16.1 参考 0.32 200 4.62 029 0.25~0.35 0.33 2 4.48 0.28 0.19~0.35 0.32 0.25 4.46 0.28 0.13~0.39 0.31 5 连续信号 4.43 参考 0.336 200 1.68 0.38 0.33~0.44 0.33 2 1.61 0.36 0.27~0.44 0.31 0.25 1.57 0.35 0.19~0.47 0.32 表 5 4号样品对短持续信号的响应4 kHz重复猝发音的参考值及误差限
Table 5. Reference value and limits of the noise dose ratio of Sample 4 for the short duration signal of 4 kHz repetitive bursts
标准评判声级 交换率/dB 猝发音持续时间/m s 噪声剂量测得值/% 噪声剂量比 噪声剂量比的误差限 噪声剂量相对测量不确定/% 90 3 连续信号 281.42 参考 0.33 200 60.79 0.22 0.16~0.25 0.36 2 55.73 0.20 0.11~0.25 0.32 0.25 54.60 0.19 0.062~0.28 0.35 4 连续信号 29.61 参考 0.31 200 9.71 0.33 0.25~0.35 0.34 2 8.82 0.30 0.19~0.35 0.32 0.25 8.65 0.29 0.13~0.39 0.34 5 连续信号 7.67 参考 0.33 200 2.86 0.37 0.33~0.44 0.35 2 2.91 0.38 0.27~0.44 0.33 0.25 2.94 0.38 0.19~0.47 0.34 -
[1] 陈克安, 曾向阳, 李海英. 声学测量[M]. 北京: 科学出版社, 2005. [2] Occupational Safety and Health standards—Occupational Noise Exposure: OSHA 29CRF 1910.95[S/OL]. [2021-05-17]. https://www.docin.com/p-1762035955.html. [3] 蒲志强, 刘湘衡, 张国庆, 等. 声学计量术语及定义: JJF 1034-2020[S]. 北京: 中国质检出版社, 2020. [4] 陈剑林, 刘定洋, 张美娥. 噪声剂量计: JJG 655-1990[S]. 北京: 中国标准出版社, 1990. [5] 章汝威. 声学 关于空气噪声的测量及其对人影响的评价的标准指南: GB/T 14259-93[S]. 北京: 中国标准出版社, 1990. [6] 吴胜举, 张明铎. 声学测量原理与方法[M]. 北京: 科学出版社, 2014. [7] Electroacoustics—Sound level meters—Part 1: Specifications IEC 61672-1: 2013[S/OL]. [2021-05-17]. https://www.doc88.com/p-5991605238335.html. [8] 刘湘衡, 陈剑林, 潘月吾. 个人声暴露计: JJG 980-2003[S]. 北京: 中国计量出版社, 2003. [9] Specification for Personal Noise: ANSI S1.25-1991(R2007)[S/OL]. [2021-05-17]. https://www.docin.com/p-345303975.html. [10] 刘湘衡, 谭庆桂, 张朋万, 等. 噪声剂量计技术条件: JB/T 6824-93[S]. 北京: 机械工业部仪表综合经济研究所出版, 1993. [11] 许欢, 白滢, 牛峰, 等. 声级计: JJG 188-2017[S]. 北京: 中国质检出版社, 2017. [12] 叶德培, 赵峰, 施彦昌, 等. 测量不确定度评定与表示: JJF 1059.1-2012[S]. 北京: 中国标准出版社, 2012.