Design and Implementation of Automatic Calibration System for Microwave Power Sensor
-
摘要: 微波功率传感器是测量微波功率的主要仪器,为保证测量结果准确一致,需要定期进行校准,将微波功率量值溯源到国家标准。为实现微波功率传感器的自动校准,研究设计了基于传递标准法的微波功率传感器自动校准系统,阐述了系统硬件组成、软件设计方法,实现了自动校准和校准因子及其扩展不确定度的自动计算,提高了工作效率和质量。Abstract: Microwave power sensor is the primary instrument for measuring microwave power. To ensure the accuracy and consistency of the values, the power sensor needs to be calibrated periodically to trace to the national standards. In order to realize the automatic calibration of the power sensor, an automatic calibration system based on the transmission standard method was designed, the hardware composition and software design method of the system were described, and the automatic calibration and the automatic calculation of the calibration factor and its expanded uncertainty were realized.
-
Key words:
- power sensor /
- automatic calibration /
- data comparison /
- calibration factors
-
表 1 校准数据比对表
Table 1. Calibration data comparison table
f/MHz 软件测量值 人工读数 Pbc/mW Pbu/mW Ku Pbc/mW Pbu/mW Ku 1000 1.0001 1.028 0.981 1.0002 1.028 0.981 2000 1.0003 1.022 0.981 1.0003 1.022 0.981 3000 0.9992 1.020 0.978 0.9992 1.020 0.978 4000 1.0001 1.023 0.977 1.0001 1.023 0.977 5000 1.0002 1.024 0.969 1.0002 1.024 0.969 表 2 校准结果表
Table 2. Calibration result table
f/MHz Ku1 Ku2 Ku3 Ku4 Ku5 Ku6 ${\overline K}_{\rm{u} }$ U/% 1000 0.981 0.983 0.981 0.981 0.982 0.981 0.982 2.5 2000 0.981 0.979 0.979 0.979 0.979 0.979 0.979 2.8 3000 0.978 0.977 0.977 0.977 0.978 0.977 0.977 3.0 4000 0.977 0.978 0.977 0.977 0.975 0.975 0.977 3.0 5000 0.969 0.968 0.969 0.969 0.967 0.968 0.968 3.0 -
[1] 吕云熙, 屈建胜, 胡炜. NRP-Z21功率传感器LABVIEW测量程序设计[J]. 计量技术, 2016(7): 30-32. [2] 潘积文. 基于Labview的功率计自动校准系统[J]. 宇航计测技术, 2009, 29(1): 55-57. [3] 陈飞, 许传忠, 唐友东, 等. 9 kHz~50 GHz宽频带小功率校准系统[J]. 国外电子测量技术, 2017, 36(3): 82-86. [4] 赵熙, 崔广新, 郑喜艳. 功率传感器自动校准软件设计与实现[J]. 计算机测量与控制, 2021, 29(3): 161-164,175. [5] 郑喜艳, 张燕, 赵熙. 功率传感器自动校准系统数据库的设计与实现[J]. 计量与测试技术, 2020, 47(4): 33-36. [6] 李春葆, 曾平, 喻丹丹. C#程序设计教程[M]. 北京: 清华大学出版社, 2010: 367-420. [7] 赵昕, 郭恩全, 朱健. 具有LXI和GPIB可编程仪器通用接口设计[J]. 单片机与嵌入式系统应用, 2021, 21(10): 88-91. [8] 周欢, 李宥谋, 黄建军, 等. 基于LXI网络仪器的自动发现与配置[J]. 计算机技术与发展, 2017, 27(12): 197-200. [9] 中国人民解放军总装备部. 小功率座检定规程: GJB/J3598-99 [S]. 北京: 总装备部军标出版发行部, 1999. [10] 孙新莉, 陈钢. RF/微波功率传感器校准方法的探讨[J]. 计量技术, 2007(6): 42-44. [11] 张伟伟, 杨绪军, 陈云梅. 相对测量标准不确定度在微波功率计量中的应用[J]. 宇航计测技术, 2015, 35(5): 1-5. [12] 陈振林, 孙中泉. 微波功率座自动校准系统不确定度分析[J]. 仪器仪表学报, 2006, 27(6): 1291-1293. [13] 李袁柳, 王玉珍, 斯中毅. 微波功率敏感器校准系统不确定度分析[J]. 自动化与仪表, 2010, 25(7): 56-57,60. [14] 靳浩元, 刘军. 测量不确定度的评定方法及应用研究[J]. 计量科学与技术, 2021, 65(5): 124-131. [15] 国家质量监督检验检疫总局. 法定计量检定机构考核规范: JJF1069-2012 [S]. 北京: 中国质检出版社, 2012.