Design of Dynamic Calibration Device for Non-Combustibility Test Furnace of Building Materials
-
摘要: 为了对建筑材料不燃性试验炉进行量值溯源,确保试验结果的准确性和可靠性,通过对试验炉温度分布模型研究,设计研制了一套建筑材料不燃性试验炉动态校准装置。装置采用热电偶高温检测和温度补偿技术对试验炉的温度进行动态检测,利用伺服电机和滑动平台实现传感器在高温炉内自动定位,利用LabVIEW处理校准数据并通过触摸显示屏输出校准结果。研制的校准装置经检测,性能达到设计要求,试验炉各参数校准的验证结果均在标准规定的范围内,校准不确定度满足量值传递要求。Abstract: To ensure the accuracy and reliability of the test results, a set of dynamic calibration device for non-combustibility test furnace of building materials was designed and developed through the study of the temperature distribution model of the test furnace. The device adopted thermocouple high-temperature detection and temperature compensation technology to realize the dynamic temperature detection of the test furnace, and the servo motor and sliding platform were designed to realize the sensor automatic positioning in the high-temperature furnace. The LabVIEW data processing technology and touch screen design were equipped to achieve calibration data processing and calibration results output. The developed calibration device was tested and its performance met the design requirements. The verification results of the calibration of each parameter of the test furnace were within the range specified by the standard, and the calibration uncertainty met the requirements for value transmission.on.
-
表 1 温度示值校准结果
Table 1. Calibration results of temperature indication error
/℃ 温度示值 YL1612 ZY6017D-PC TH-FCB 校准结果 示值误差 校准结果 示值误差 校准结果 示值误差 650 646.3 3.7 647.2 2.8 650.6 −0.6 700 698.1 1.9 698.0 2.0 702.1 −2.1 750 747.6 2.4 749.1 0.9 751.5 −1.5 800 803.5 −3.5 797.6 2.4 803.8 −3.8 850 854.7 −4.7 848.5 1.5 851.9 −1.9 表 2 炉壁温度校准结果
Table 2. Calibration results of furnace wall temperature
测量点 YL1612
校准结果ZY6017D-PC
校准结果TH-FCB
校准结果T1a 751.6℃ 750.6℃ 751.6℃ T1b 753.1℃ 751.6℃ 752.2℃ T1c 755.1℃ 752.4℃ 754.4℃ T2a 753.2℃ 751.2℃ 753.1℃ T2b 753.7℃ 752.1℃ 753.7℃ T2c 755.8℃ 752.8℃ 754.8℃ T3a 754.4℃ 752.7℃ 755.6℃ T3b 753.9℃ 752.8℃ 755.1℃ T3c 758.5℃ 753.2℃ 756.5℃ 炉壁a位置平均温度 753.07℃ 751.50℃ 753.43℃ 炉壁c位置平均温度 756.47℃ 752.80℃ 755.23℃ 炉壁轴向炉温偏差TADa 0.11% 0.07% 0.14% 炉壁径向炉温偏差TADl 0.19% 0.29% 0.11% -
[1] 张羽, 姚建军, 邓小兵. 建筑材料不燃性试验方法: GB/T 5464 - 2010[S]. 北京: 中国标准出版社, 2019. [2] 徐晶晶, 王力. 建筑材料不燃性试验中一些问题的探讨[J]. 标准科学, 2018(10): 121-123. doi: 10.3969/j.issn.1674-5698.2018.10.024 [3] 崔福林, 季广其. 复合材料不燃性试验方法初探[J]. 消防技术与产品信息, 1997(3): 13-16. [4] 李晗, 李飞. 保温材料不燃性试验的探讨[J]. 计量与测试技术, 2021(5): 56-59. doi: 10.15988/j.cnki.1004-6941.2021.5.018 [5] 李守德. 我国建筑材料难燃性能试验装置及试验方法[J]. 消防技术与产品信息, 1994(1): 6-7. [6] 梁新荣, 刘智勇. 集成温度传感器多点温度检测系统的设计[J]. 仪表技术与传感器, 2003(7): 18-19. doi: 10.3969/j.issn.1002-1841.2003.07.007 [7] 李雪娇, 屈新鑫, 熊雅玲, 等. 浅谈铂铑热电偶测温准确性的影响因素[J]. 贵金属, 2018, 39(4): 74-82. doi: 10.3969/j.issn.1004-0676.2018.04.012 [8] 范铠, 张继培. 热电偶 第二部分: 允差: GB/T 16839.2-1997[S]. 北京: 中国标准出版社, 1997. [9] 董晓红. 一种高温电阻炉的温度检测系统[D]. 乌鲁木齐: 新疆石油学院, 2003. [10] 梁新荣. 高精度多路温度检测系统的研制[J]. 仪表技术与传感器, 2001(6): 16-17, 27. doi: 10.3969/j.issn.1002-1841.2001.06.007 [11] 于伟江. 利用现代多媒体技术实现不燃性试验中试样燃烧状态及持续燃烧时间的自动记录和存储[J]. 数字技术与应用, 2012(10): 14-17. doi: 10.19695/j.cnki.cn12-1369.2012.10.091 [12] 曹海平. 基于单片机和DS18B20的分布式多点温度检测系统的设计[J]. 自动化技术与应用, 2008(11): 90-92, 127. doi: 10.3969/j.issn.1003-7241.2008.11.026 [13] 夏志鹏, 熊芝, 陈海林, 等. 自动检测平台精确引导系统标定方法及实现[J]. 仪器技术与传感器, 2022(1): 99-103. [14] 段晓英, 孙克龙, 王雪芹. 双电机驱动的精密伺服转台及控制系统设计[J]. 机械与电子, 2021, 39(4): 49-51. doi: 10.3969/j.issn.1001-2257.2021.04.010 [15] 马西秦, 许振中. 自动检测技术[M]. 北京: 机械工业出版社, 2000: 16-37.