摘要: 为探索研究反康技术在γ能谱测量应用中的规律及有效性,在实验室利用CSS-D-60型反康普顿γ能谱仪系统进行了铀矿标物的反康测量研究,分别针对铀钍混合、铀镭平衡和单钍粉末样品进行了实测统计,获取了各类样品中186~1847 keV能量段的康普顿散射光子在实测谱中的占比分布。实验结果表明,反康普顿修正数据占比随着能量的增加呈上升趋势,在1001 keV能峰处的修正百分占比超60%。研究成果能够为γ能谱测铀技术装备的研发提供重要数据借鉴。Abstract: To explore the effectiveness and application of anti-Compton technology in γ spectrum measurements, an anti-Compton measurement study of uranium ore standards was conducted in the laboratory using the CSS-D-60 type anti-Compton γ spectrometer system. Specific measurements were taken for mixed uranium-thorium, uranium-radium equilibrium, and single thorium powder samples. The proportion distribution of Compton scattering photons in the measured spectrum in the energy range of 186-1847 keV for these various samples was obtained. The experimental results show that the proportion of anti-Compton correction data increases with energy, and the correction percentage at the 1001 keV energy peak, which is of interest in direct uranium measurement technology, exceeds 60%. The research results can provide important data references for the development of γ spectrum-based uranium measurement technology and equipment.
-
表 1 实验采用的国家一级放射性标准物质数据表
Table 1. Data table of national radioactive standard materials used in the experiment
序号 国内统一编号 名 称 比活度/ Bq·g−1 标物质量/g 1 GBW04305a 铀镭平衡粉末源 238U 39.50 / 226Ra 38.80 350.40 2 GBW04308 钍粉末源 232Th 13.90 350.34 3 GBW04127a 铀钍钾天然系矿石粉末 238U 9.31 /226Ra 9.45 / 232Th 2.96 / 40K 1.13 302.50 表 2 GBW04127a实测谱统计分析数据表
Table 2. Statistical analysis data table of the GBW04127a measured spectrum
序号 峰位左/keV 峰位右/keV 峰位/keV 全谱统计数据/cps 反康修正数据/cps 反康效果/% 1 184 187 186 1.421 0.001 0.05% 2 237 240 238 2.461 0.078 3.18% 3 293 296 295 1.678 0.110 6.54% 4 336 339 338 5.987 0.255 4.25% 5 348 354 352 2.024 0.340 16.82% 6 461 464 463 1.054 0.525 49.81% 7 607 611 609 1.376 0.663 48.18% 8 725 729 727 1.212 0.670 55.26% 9 784 787 786 0.948 0.479 50.55% 10 908 913 911 1.434 0.577 40.23% 11 966 971 969 0.862 0.539 62.53% 12 998 1003 1001 1.060 0.665 62.72% 13 1117 1122 1120 0.756 0.435 57.48% 14 1235 1240 1238 0.560 0.390 69.70% 15 1405 1410 1408 0.449 0.362 80.57% 16 1456 1463 1461 0.603 0.486 80.66% 17 1493 1498 1496 0.441 0.363 82.37% 18 1540 1545 1543 0.451 0.374 82.90% 19 1585 1590 1588 0.552 0.430 78.02% 20 1617 1623 1621 0.505 0.419 83.05% 21 1658 1663 1661 0.429 0.356 82.90% 22 1725 1732 1730 0.474 0.378 79.69% 23 1759 1767 1764 0.484 0.386 79.70% 24 1843 1850 1847 0.444 0.352 79.22% 表 3 GBW04305a实测谱统计分析数据表
Table 3. Statistical analysis data table of the GBW04305a measured spectrum
序号 峰位左/keV 峰位右/keV 峰位/keV 全谱统计数据/cps 反康修正数据/cps 反康效果/% 1 184 187 186 4.489 0.008 0.17% 2 237 240 238 6.848 0.122 1.78% 3 293 296 295 4.927 0.011 0.22% 4 336 339 338 14.548 1.513 10.40% 5 348 354 352 6.096 0.822 13.49% 6 461 464 463 3.169 1.551 48.95% 7 607 611 609 4.319 1.958 45.33% 8 725 729 727 3.742 1.988 53.12% 9 784 787 786 3.133 1.397 44.57% 10 908 913 911 4.658 1.725 37.04% 11 966 971 969 2.711 1.550 57.18% 12 998 1003 1001 3.720 2.238 60.16% 13 1117 1122 1120 2.152 1.255 58.34% 14 1235 1240 1238 1.694 1.121 66.19% 15 1405 1410 1408 1.345 1.046 77.75% 16 1456 1463 1461 1.775 1.405 79.14% 17 1493 1498 1496 1.322 1.069 80.89% 18 1540 1545 1543 1.336 1.095 81.95% 19 1585 1590 1588 1.787 1.366 76.43% 20 1617 1623 1621 1.625 1.343 82.61% 21 1658 1663 1661 1.371 1.134 82.66% 22 1725 1732 1730 1.360 1.079 79.38% 23 1759 1767 1764 1.432 1.136 79.33% 24 1843 1850 1847 1.337 1.045 78.18% 表 4 GBW04308实测谱统计分析数据表
Table 4. Statistical analysis data table of the GBW04308 measured spectrum
序号 峰位左/keV 峰位右/keV 峰位/keV 全谱统计数据/cps 反康修正数据/cps 反康效果/% 1 184 187 186 1.564 0.003 0.21% 2 237 240 238 2.857 0.003 0.10% 3 293 296 295 1.969 0.012 0.63% 4 336 339 338 2.331 0.003 0.14% 5 348 354 352 2.515 0.243 9.67% 6 461 464 463 1.394 0.677 48.56% 7 607 611 609 1.538 0.797 51.80% 8 725 729 727 1.430 0.822 57.49% 9 784 787 786 1.208 0.725 60.01% 10 908 913 911 1.460 0.827 56.64% 11 966 971 969 1.027 0.770 74.90% 12 998 1003 1001 0.985 0.737 74.86% 13 1117 1122 1120 1.057 0.611 57.76% 14 1235 1240 1238 0.721 0.556 77.13% 15 1405 1410 1408 0.608 0.488 80.29% 16 1456 1463 1461 0.807 0.649 80.39% 17 1493 1498 1496 0.594 0.481 81.04% 18 1540 1545 1543 0.582 0.474 81.41% 19 1585 1590 1588 0.550 0.444 80.69% 20 1617 1623 1621 0.574 0.458 79.80% 21 1658 1663 1661 0.462 0.366 79.24% 22 1725 1732 1730 0.640 0.507 79.26% 23 1759 1767 1764 0.669 0.536 80.02% 24 1843 1850 1847 0.534 0.424 79.39% -
[1] 吴和喜, 杨波, 魏强林, 等. 线极化γ射线康普顿散射的蒙特卡罗模拟[J]. 原子能科学技术, 2013, 47(8): 1286-1289. [2] 刘超卓, 张建强, 孙立杰, 等. γ射线康普顿散射的能谱研究[J]. 核电子学与探测技术, 2012, 32(10): 1178-1182. doi: 10.3969/j.issn.0258-0934.2012.10.017 [3] 吴和喜, 袁新宇, 刘庆成, 等. 一种γ谱弱峰优化检测方案研究[J]. 原子能科学技术, 2012, 46(9): 1142-1146. doi: 10.7538/yzk.2012.46.09.1142 [4] 李根, 魏凡, 楼建玲. NaI(Tl)谱仪中反散射峰的影响因素研究[J]. 大学物理, 2019, 38(4): 63-67. [5] 魏凡, 李根, 楼建玲. 抑制NaI(Tl)谱仪中反散射峰的简便实验方法[J]. 大学物理, 2019, 38(6): 55-59. [6] 曾国强, 葛良全, 胡传皓, 等. 反康普顿航空伽马能谱测量系统及其测量方法: 202010965672.1[P]. 2020-9-15. [7] 赵剑锟, 葛良全, 罗耀耀, 等. 反康普顿散射探测器: 201510885324.2[P]. 2015-12-7. [8] 焦海波, 解鹏飞, 王家恒, 等. 一种宽频带低噪声测量放大器的设计[J]. 计量科学与技术, 2023, 67(11): 3-9. [9] 冯延强, 王海洋, 王铁建, 等. 基于新型CeBr3探测器井下γ能谱测量238U关键技术研究[J]. 原子能科学技术, 2021, 55: 422-428. doi: 10.7538/yzk.2021.zhuankan.0138 [10] 冯延强, 王铁健, 杨龙泉, 等. 利用新型CeBr3探测器测量238U活度研究[J]. 核技术, 2021, 44(3): 1-6. [11] 高天恒, 任同祥, 王松. 基于LA-ICP-MS的软质样品定量分析研究进展[J]. 计量科学与技术, 2023, 67(1): 29-38. [12] LI Xinchi, ZENG Guoqiang, YAN Lei, et al. Design of a time discriminator in a low-background, anti-compton spectrometer[J]. Materials Science and Engineering, 2019, 631: 1-10. [13] ZHANG Weihua, MEKARSKI Pawel, DION Maxime, et al. A digital compton suppression spectroscopy without gamma-ray coincidence-summing loss using list-mode multispectral data acquisition[J]. Journal of Radioanalytical & Nuclear Chemistry, 2012, 292: 1265-1272. [14] 汤彬, 吴永鹏, 张雄杰, 等. 高精度能谱测井与234Pam特征γ射线的“直接铀定量”技术[J]. 核技术, 2012, 35(10): 745-750. [15] 郭瑞民. 气体光谱计量技术研究进展[J]. 计量科学与技术, 2022, 66(10): 52-56. [16] 吴永鹏, 汤彬, 程建平, 等. 利用LaBr3(Ce)伽马谱仪直接测定铀矿体中铀含量的方法[J]. 物探与化探, 2012, 36(3): 414-417. [17] 刘培源, 李剑, 夏春, 等. 多种气体对烟气分析仪中电化学传感器的交叉干扰研究[J]. 计量科学与技术, 2023, 67(7): 62-67,52. [18] 高天恒, 任同祥. 不同聚合物基质的LA-ICP-MS剥蚀行为探究[J]. 计量科学与技术, 2023, 67(4): 63-69.