Research on Remote Time Traceability Technology Based on Satellite Common-View Atomic Clock Discipline Method
-
摘要: 通过建立卫星共视原子钟驯服装置,将本地原子时与国家时间频率基准参考站进行共视比对,实现了铷原子钟的驯服标准差2.19 ns,时间偏差稳定度(1天)小于1×10−9,相对频率偏差−8.42×10−17,频率稳定度(1天)小于2×10−14;铯原子钟的驯服标准差1.5 ns,时间偏差稳定度(1天)小于1×10−9,相对频率偏差7.03×10−17,频率稳定度(1天)小于1×10−14。本地原子时得到有效的溯源,为完善时间标准的检定系统表提供了技术验证。Abstract: In this paper, through the establishment of a satellite common-view atomic clock discipline device, the local atomic time is compared with the national time and frequency reference station. Results show that the standard deviation of the rubidium clock is 2.19 ns, the stability of time deviation (1 day) is less than 1×10−9, the relative frequency deviation is −8.42×10−17, the frequency stability (1 day) is less than 2×10−14, and the discipline standard deviation of cesium clock is 1.5 ns. The stability of time deviation (1 day) is less than 1×10−9, the relative frequency deviation is 7.03×10−17, and the frequency stability (1 day) is less than 1×10−14. The local atomic time is effectively traced and provides technical validation to improve the verification system table of the time standard.
-
Key words:
- discipline /
- satellite common-view /
- time standard /
- time frequency /
- time traceability
-
表 1 TS17时间偏差数据统计
Table 1. TS17 time deviation data statistics
观测站
(REF)观测
点数0<|**|
<5 ns5 ns<|**|
<10 ns10 ns<|**|
<20 ns|**|
>20 nsTS17 7523 7305 190 18 11 97.10% 2.52% 0.23% 0.15% 表 2 TF16时间偏差数据统计
Table 2. TF16 time deviation data statistics
观测站
(REF)观测
点数0<|**|
<5 ns5 ns<|**|
<10 ns10 ns<|**|
<20 ns|**|
>20 nsTF16 7496 7338 133 22 3 97.89% 1.78% 0.29% 0.04% -
[1] 王晔, 梁坤, 王剑. 多种GNSS时频传递接收机性能的实验比对[J]. 计量技术, 2017(10): 3-6, 11. doi: 10.3969/j.issn.1000-0771.2017.10.01 [2] 张斌, 张东来. 基于 GPS 的高精度时钟在线校频与授时研究[J]. 中国电机工程学报, 2012, 32(10): 22, 160-167. [3] François Lahaye, Giancarlo Cerretto, Patrizia Tavella. GNSS geodetic techniques for time and frequency transfer applications[J]. Advances in Space Research, 2011, 47(2): 253-264. [4] 范兴民. 基于北斗GPS共视技术的机场站点高精度时间同步方法[J]. 电子世界, 2019(20): 63-64. [5] Kun L, Qingyi C, Kai H, et al. REPLICATING UTC(NIM) REMOTELY FOR TIME AND FREQUENCY TRACEABILITY[J]. IJEE, 2019, 26(4): 147-155. [6] 国家市场监督管理总局. 时间与频率标准远程校准规范: JJF 1206-2018[S]. 北京, 2018. [7] 张思德. 一种基于全球导航卫星系统的标准时间频率源装置: 201921555556.1 [P]. 2019-09-16. [8] 张思德. 一种基于北斗/GPS共视的时间传递装置: 201620497199.8[P]. 2016-05-26. [9] Kun L, Hang Y, Fei Z, et al. Disciplined oscillator system by UTC(NIM) for remote time and frequency traceability[C]. European Frequency & Time Forum. IEEE, 2015. [10] 杨帆, 杨军, 徐月青. 基于时间传递型GNSS接收机的铯原子频标驾驭方法研究[C]. 第六届中国卫星导航学术年会. 西安: 电子技术及信息科学, 2015: 5. [11] Liang, Kun; Zuo, Fei; Pei, Chao; Zhang, Side; Zhang, Aimin, Real-Time Remote Calibration (RTRC) System for Time and Frequency[C]. IFCS-EFTF, 2013. [12] 龙波, 尤捷雯, 张宇, 等. 基于NIMDO的远程时间频率溯源[J]. 计量与测试技术, 2019, 46(8): 9-11.