Citation: | HANG Chenzhe, XU Dinghua, YUAN Zundong. Research on Chi-Square Statistics in Data Analysis of Inter-laboratory Comparison[J]. Metrology Science and Technology, 2021, 65(5): 108-114. doi: 10.12338/j.issn.2096-9015.2020.9042 |
[1] |
原遵东, 王池, 林延东. 确定量值比对参考值的准则[J]. 仪器仪表学报, 2010, 31(10): 2381-2385.
|
[2] |
张海云, 吴忠杰, 杭晨哲, 等. MCMC法确定关键比对参考值及其不确定度[J]. 计量技术, 2020(7): 3-7, 26. doi: 10.3969/j.issn.1000-0771.2020.07.01
|
[3] |
Cox M G. The evaluation of key comparison data[J]. Metrologia, 2002, 39(6): 589-595. doi: 10.1088/0026-1394/39/6/10
|
[4] |
Koepke A, Lafarge T, Possolo A, et al. Consensus building for interlaboratory studies, key comparisons, and meta-analysis[J]. Metrologia, 2017, 54(3): S34-S62. doi: 10.1088/1681-7575/aa6c0e
|
[5] |
Toman B, Possolo A. Laboratory effects models for interlaboratory comparisons[J]. Accred Qual Assur, 2009, 14(10): 553-563. doi: 10.1007/s00769-009-0547-2
|
[6] |
Elster C, Toman B. Analysis of key comparisons: estimating laboratories’ biases by a fixed effects model using Bayesian model averaging[J]. Metrologia, 2010, 47(3): 113-119. doi: 10.1088/0026-1394/47/3/001
|
[7] |
Steele A G, Douglas R J. Extending chi-squared statistics for key comparisons in metrology[J]. Journal of Computational and Applied Mathematics, 2006(192): 51-58.
|
[8] |
Rukhin A L. Weighted means statistics in interlaboratory studies[J]. Metrologia, 2017, 46(3): 323-331.
|
[9] |
Toman B, Fischer J, Elster C. Alternative analyses of measurements of the Planck constant[J]. Metrologia, 2012, 49(4): 567-571. doi: 10.1088/0026-1394/49/4/567
|
[10] |
Paule R C, Mandel J. Consensus values and weighting factors[J]. J. Res. Natl Bureau Stand, 1982, 87(5): 377-385. doi: 10.6028/jres.087.022
|
[11] |
Graybill F A, Deal R B. Combining unbiased estimators[J]. Biometrics, 1959(15): 543-550.
|
[12] |
BIPM. CCQM guidance note: estimation of a consensus KCRV and associated degrees of equivalence[DB/OL]. http://www.bipm.org/cc/CCQM/Allowed/19/CCQM13-22_Consensus_KCRV_v10.pdf, 2013: 23-25.
|