SHEN Jianguo, WANG Caiqin, LIU Kanglu, SUN Xiaopeng. Discussions on Capacity Verification of Vertical Metal Tanks[J]. Metrology Science and Technology, 2021, 65(11): 40-44, 71. DOI: 10.12338/j.issn.2096-9015.2021.0034
    Citation: SHEN Jianguo, WANG Caiqin, LIU Kanglu, SUN Xiaopeng. Discussions on Capacity Verification of Vertical Metal Tanks[J]. Metrology Science and Technology, 2021, 65(11): 40-44, 71. DOI: 10.12338/j.issn.2096-9015.2021.0034

    Discussions on Capacity Verification of Vertical Metal Tanks

    • Vertical metal tanks (hereinafter referred to as vertical tanks) are a measurement instrument that requires compulsory verification. The measurement accuracy directly relates to trading parties’ economic interests. This paper discusses factors affecting accuracy of volume measurements of vertical metal tanks, including the incident angle’s effect (no more than 60°) in total station surveying, the correlation between inputs in uncertainty evaluation for radial deviation measurements, the strapping method for measuring the base circle, and dealing with the outliers when fitting the measurement center and radius.
    • loading

    Catalog

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return