Volume 66 Issue 2
Feb.  2022
Turn off MathJax
Article Contents
JIN Xiangchun, XIAO Caijin, YAO Yonggang, ZHANG Junxin, WU Peng, WANG Pingsheng, NI Bangfa. Quality Assurance of Neutron Activation Analysis for the Determination of Atmospheric Particulate Matter Elements[J]. Metrology Science and Technology, 2022, 66(2): 9-14. doi: 10.12338/j.issn.2096-9015.2021.0553
Citation: JIN Xiangchun, XIAO Caijin, YAO Yonggang, ZHANG Junxin, WU Peng, WANG Pingsheng, NI Bangfa. Quality Assurance of Neutron Activation Analysis for the Determination of Atmospheric Particulate Matter Elements[J]. Metrology Science and Technology, 2022, 66(2): 9-14. doi: 10.12338/j.issn.2096-9015.2021.0553

Quality Assurance of Neutron Activation Analysis for the Determination of Atmospheric Particulate Matter Elements

doi: 10.12338/j.issn.2096-9015.2021.0553
  • Available Online: 2021-12-31
  • Publish Date: 2022-02-18
  • The instrumental neutron activation analysis has advantages including high sensitivity, no need for sample pretreatment, and a wide variety of measurable elements. It is one of the common methods for analyzing the element content of atmospheric particulate matter and can provide an important data basis for the analysis of pollution sources. This article summarizes the quality assurance process of each experimental process in the NAA laboratory using the relative comparison method and the single comparator k0 method to analyze atmospheric particulate matter samples, as well as internal and external quality control methods.
  • loading
  • [1]
    汤桦, 赵新颖, 叶昌俊, 等. SPLE-GC-NCI-IDMS测定大气颗粒物中27种硝基多环芳烃[J]. 计量技术, 2020(5): 68-73.
    [2]
    王颖, 汤桦, 吴雪, 等. 大气颗粒物中PFOA和PFOS检测方法的研究进展[J]. 计量科学与技术, 2020(9): 34-40. doi: 10.3969/j.issn.1000-0771.2020.09.08
    [3]
    吴丹, 高晓晶, 廖小卿, 等. 大气重金属在线监测系统的评价[J]. 计量科学与技术, 2021, 65(3): 32-35.
    [4]
    GREENBERG R R, BODE P, FERNANDES E. Neutron activation analysis: A primary method of measurement[J]. Spectrochimica Acta Part B Atomic Spectroscopy, 2011, 66(3-4): 193-241. doi: 10.1016/j.sab.2010.12.011
    [5]
    FREITAS A C M. Sources of trace elements in fine and coarse particulate matter in a sub-urban and industrial area of the Western European Coast[J]. Procedia Environmental Sciences, 2011, 4: 184-191. doi: 10.1016/j.proenv.2011.03.022
    [6]
    FREITAS M C, ALMEIDA S M, REIS M A, et al. Neutron activation analysis: Still a reference method for air particulate matter measurements[J]. Journal of Radioanalytical Nuclear Chemistry, 2004, 262(1): 235-239. doi: 10.1023/B:JRNC.0000040880.76829.0d
    [7]
    YANG J, LIU G, YAO Y, et al. Elemental analysis of PM2.5 using PIXE and NAA in Xinzhen, Beijing[J]. Journal of Radioanalytical and Nuclear Chemistry, 2020, 323(11): 457-463.
    [8]
    杨伟涛, 刘存兄, 黄东辉, 等. 大气颗粒物PM10和PM2.5元素组成的中子活化分析[J]. 原子能科学技术, 2007, 41(2): 228-231. doi: 10.3969/j.issn.1000-6931.2007.02.021
    [9]
    ALGHEM L H. Advanced Technologies and Applications of Neutron Activation Analysis [M]. Advanced Technologies and Applications of Neutron Activation Analysis, 2019.
    [10]
    国家市场监督管理总局, 国家标准管理委员会. 检测和校准实验室能力的通用要求: GB/T 27025-2019 [S]. 北京: 中国标准出版社, 2019.
    [11]
    蒋京鑫. 对新版ISO/IEC 17025标准中判定规则应对措施的探讨[J]. 质量与认证, 2020, 167(9): 76-77.
    [12]
    CHUNG K H, CHOI G S, LEE W, et al. Implementation of ISO/IEC 17025 standard in a nuclear analytical laboratory: The KAERI experience[J]. Accreditation and quality assurance, 2006, 10(11): 693-705.
    [13]
    GLAVIČ-CINDRO D, KORUN M J A. Influence of a quality system complying with the requirements of ISO/IEC 17025 standard on the management of a gamma-ray spectrometry laboratory[J]. Accreditation and Quality Assurance, 2006, 10(11): 609-612. doi: 10.1007/s00769-005-0064-x
    [14]
    SIMONITS A, CORTE F D, HOSTE J. Single-comparator methods in reactor neutron activation analysis[J]. Journal of Radioanalytical Chemistry, 1975, 24(1): 31-46. doi: 10.1007/BF02514380
    [15]
    SIMONITS A, MOENS L, CORTE F D, et al. ko-measurements and related nuclear data compilation for (n, γ) reactor neutron activation analysis[J]. Journal of Radioanalytical Chemistry, 1980, 60: 461-516. doi: 10.1007/BF02518906
    [16]
    MOENS L, CORTE F, WISPELAERE A D, et al. ko-Measurements and related nuclear data compilation for (n, γ) reactor neutron activation analysis, part II[J]. Journal of Radioanalytical Nuclear Chemistry, 1984, 82(2): 385-452. doi: 10.1007/BF02037061
    [17]
    CORTE F D, SIMONITS A, WISPELAERE A D, et al. Accuracy and applicability of the k0-standardization method[J]. Journal of Radioanalytical Nuclear Chemistry, 1987, 113(1): 145-161. doi: 10.1007/BF02036056
    [18]
    CORTE F D. k0 and Comparator NAA: Influences and Interactions[J]. Journal of Radioanalytical and Nuclear Chemistry, 2000, 245: 157-161. doi: 10.1023/A:1006785417003
    [19]
    RIDIKAS D, BARRADAS N P, MIGLIORI A, et al. Improved performance of neutron activation analysis laboratories by feedback workshops following interlaboratory comparison rounds[J]. Accreditation and Quality Assurance, 2021, 26(3): 1-8.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Tables(2)

    Article Metrics

    Article views (615) PDF downloads(38) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return